HZD-B-8B一體化振動(dòng)變送器技術(shù)參數(shù)
2.1 頻率響應(yīng):10 ~ 1000 Hz * 或者5-1000 Hz(特殊說(shuō)明)
2.2 自振頻率:10Hz
2.3 測(cè)量范圍:0-20mm/s
2.4 輸出電流:4~20mA
2.5輸出阻抗:≤500Ω
2.6工作電壓:DC12-36V
2. 7接線方式:二線制
2.7最大加速度:10g
2.8測(cè)量方向:通用(垂直或水平)
2.9 使用環(huán)境:溫 度 -40℃~+85℃ 相對(duì)濕度 ≤90%
2.10 外形尺寸:φ33mm×76mm
2.11 安裝:M10*1.5或其他規(guī)格
2.12 重 量: 約350g
3. 13 外殼材質(zhì):304不銹鋼
3.安 裝
3.1 安裝位置:垂直或者水平安裝于被測(cè)振動(dòng)點(diǎn)上,將傳感器固定在被測(cè)殼體上,然后將傳器擰在上面吸附即可。
3.2 安裝尺寸及規(guī)范:參看圖一,若變送器安裝位置受到高溫蒸汽等沖刷時(shí),為降低變送器環(huán)境溫度、需加防護(hù)措施,一般情況下可不加防護(hù)。
3.3 接線說(shuō)明:棕色導(dǎo)線接DC24V電源正端,藍(lán)色導(dǎo)線接4-20mA輸出,。連接導(dǎo)線要求有良好的絕緣性能,采用二芯屏蔽電纜。
3. 注意事項(xiàng)
4. 1變送器應(yīng)防止劇烈碰撞和敲打。
2運(yùn)輸過(guò)程和儲(chǔ)存時(shí)應(yīng)置于專用包裝盒內(nèi)。
HZD-B-8B Integrated Vibration Transmitter
By integrating the magnetic-electric vibration sensor and the precise measurement circuit, a high-precision vibration measurement system is formed. This transmitter can be directly connected to DCS, PLC or other devices, and is an ideal choice for measuring the vibration of factory equipment such as fans, motors and water pumps.
Technical parameters of HZD-B-8B integrated vibration transmitter
2.1 Frequency Response: 10 - 1000 Hz * or 5 - 1000 Hz (if specified)
2.2 Natural Frequency: 10 Hz
2.3 Measurement Range: 0 - 20 mm/s
2.4 Output Current: 4 - 20mA
2.5 Output Impedance: ≤ 500Ω
2.6 Operating Voltage: DC 12 - 36V
2. 7-wire connection method: Two-wire system
2.7 Maximum acceleration: 10g
2.8 Measurement Direction: General (Vertical or Horizontal)
2.9 Operating Environment: Temperature -40℃ to +85℃; Relative Humidity ≤ 90%
2.10 Dimensions: φ33mm × 76mm
2.11 Installation: M10*1.5 or other specifications
2.12 Weight: Approximately 350g
3. 13 Shell material: 304 stainless steel
3. Installation
3.1 Installation Position: Install vertically or horizontally on the vibration measurement point. Fix the sensor onto the measured shell, and then screw the transducer onto it to attach it.
3.2 Installation Dimensions and Specifications: Refer to Figure 1. If the installation position of the transmitter is exposed to high-temperature steam or other corrosive substances, in order to reduce the ambient temperature of the transmitter, protective measures should be taken. Generally, no protection is required.
3.3 Wiring Instructions: The brown wire is connected to the positive terminal of the DC24V power supply, and the blue wire is connected to the 4-20mA output. The connecting wires must have good insulation performance and should be connected using a two-core shielded cable.
3. Important Notes
4. 1 The transmitter should be protected from severe impacts and knocks.
During transportation and storage, it should be placed in a dedicated packaging box.